RDE-2 Rotating Disk Electrode, complete
QVEF1100
RDE-2 Rotating Disk Electrode, complete
Key features:
RDE-2 Rotating Disk Electrode, complete
Product number | QVEF1100 |
OEM reference | EF-1100 |
Application type |
|
Key features:
- Compatible with BASi stationary voltammetry electrodes
- Standard addition port
- Easy and rapid exchange of electrodes
- Low-noise electrode contact
- Excellent rotation speed accuracy, acceleration and deceleration
- Cell volume approximately 10 mL
- Optional water-jacketed cell vial
The BASi® RDE-2 is a rotator system for both fixed rotation rate and hydrodynamic modulation rotating disk electrochemical experiments. The short titanium shaft and 1/4" diameter electrode provide for an extremely low-inertia system capable of rotation rates from 50 to 10,000 RPM at better than 1% accuracy. The rotator unit is manually raised and lowered, and can be inverted for spin-coating. Rotation and built-in gas purging functions can be controlled remotely using a BASi® PC-controlled potentiostat, or manually.
The built-in gas control allows purging or blanketing of the sample prior to or during analysis. The cell arm with detachable cell top allows easy access to the electrodes for rinsing and cleaning, and the cell top is also compatible with BASi® voltammetry working electrodes. Electrodes are easily interchangeable, and the cell vial base pivots for easy removal and replacement of the cell vial.
System includes:
QVMF2066 - Glassy Carbon Electrode (1x)
QVMW1033 - Coiled Platinum wire auxiliary Electrode (1x)
QVMF1208 - Glass Cell Vials (12/pk) (1x)
QVMF2052 - RE-5B Reference Electrode (3x)
QVEW7526 - Control Cable 37 pin female to 37 pin male (1x)
QVMF2060 - PK-4 Polishing Kit (1x)
QVMR4404 - Gas Inlet Barb Fitting (1x)
QVMR5275 - Reference Electrode Storage Vial with Cap (1x)
QVMW1034 - Cell top plug (1x)
QVMF1998 - Cell lead clips kit (1x)
The built-in gas control allows purging or blanketing of the sample prior to or during analysis. The cell arm with detachable cell top allows easy access to the electrodes for rinsing and cleaning, and the cell top is also compatible with BASi® voltammetry working electrodes. Electrodes are easily interchangeable, and the cell vial base pivots for easy removal and replacement of the cell vial.
System includes:
QVMF2066 - Glassy Carbon Electrode (1x)
QVMW1033 - Coiled Platinum wire auxiliary Electrode (1x)
QVMF1208 - Glass Cell Vials (12/pk) (1x)
QVMF2052 - RE-5B Reference Electrode (3x)
QVEW7526 - Control Cable 37 pin female to 37 pin male (1x)
QVMF2060 - PK-4 Polishing Kit (1x)
QVMR4404 - Gas Inlet Barb Fitting (1x)
QVMR5275 - Reference Electrode Storage Vial with Cap (1x)
QVMW1034 - Cell top plug (1x)
QVMF1998 - Cell lead clips kit (1x)
- Remote control of stirring and gas purging by BASi® PC-controlled potentiostats
- Manual control when used with other potentiostats
- Small sample volume (10 - 15 mL)
- Optional water-jacketed cell vials
- Standard addition port
- "Quick-connect" input gas line connector
- Mounted cell top compatible with BASi® stationary voltammetry electrodes
- Easy and rapid exchange of electrodes
- Low-noise electrode contact
- Excellent rotation speed, acceleration and deceleration
- Standard package
- Cell stand with gas purge capabilities
QVMF2052,RE-5B Ag/AgC Reference Electrode, 6x75mm
QVMF1208,Glass cell vial for voltammetry, 50x59mm, 5-15 mL 12/pk
QVMW1033,Coiled Platinum Wire Auxiliary Electrode, 0,5x230mm
QVMF2166,RDE Carbon Steel Metal Insert - 6.35mm diameter x 5mm long
QVMF2166XL,RDE Carbon Steel Metal Insert - 6.35mm diameter x 40mm long
QVMF2165,RDE Double-threaded Electrode Body - 25 mm long
QVMF2165XL,RDE Double-threaded Electrode Body - 60 mm long
QVMF2067,Platinum Electrode (Pt) for RDE - 3.0 mm Diameter